What are the causes of damage to the sealing surface of the instrument valve?


Release date:

2023-02-27

The instrument valve manufacturer stated: During the production process, in order to ensure that parameters such as the pressure and flow of the medium meet the requirements of the process flow, it is necessary to install a regulating mechanism to adjust these parameters. The main working principle of the regulating mechanism is to adjust the above parameters by changing the flow area between the valve plug and the valve seat.

  The instrument valve manufacturer states: During the production process, in order to ensure that parameters such as the pressure and flow of the medium meet the requirements of the process flow, it is necessary to install an adjustment mechanism to regulate these parameters. The main working principle of the adjustment mechanism is to regulate the parameters by changing the flow area between the valve plug and the valve seat. Causes of damage to the sealing surface of the instrument valve include both human-induced and natural damage. Human-induced damage is caused by poor design, poor manufacturing, improper material selection, incorrect installation, improper use, and poor maintenance. Natural damage refers to wear under normal working conditions and damage caused by inevitable erosion and impact of the medium on the sealing surface. Below are the causes of damage to the sealing surface of the instrument valve:

  1. Poor processing quality of the sealing surface, mainly manifested as cracks, pores, and inclusion defects on the sealing surface. This is due to improper selection of welding and heat treatment specifications, as well as operational issues during welding and heat processing. Excessively high or low hardness of the cover is caused by incorrect material selection or improper heat treatment. Uneven hardness and poor corrosion resistance of the sealing surface are mainly due to swelling and dilution of the base metal during welding. These issues are caused by the alloy composition of the sealing surface. Of course, design problems also exist.

  2. Improper installation and maintenance lead to abnormal operation of the sealing surface, defective operation of the drain valve, and premature damage to the sealing surface of the instrument valve.

  3. Damage caused by improper selection and operation. The main issue is failing to select the instrument valve according to working conditions, using a shut-off valve as a throttle valve, resulting in excessive sealing pressure, sealing that is too fast or too tight, and erosion and wear of the sealing surface.

  4. Mechanical damage. During opening and closing, the sealing surface can be scratched, rubbed, or crushed. Between the two sealing surfaces, atoms penetrate each other under high temperature and high pressure, causing adhesion. When the two sealing surfaces move relative to each other, the adhesive force is easily pulled apart, and the higher the surface roughness of the sealing surface, the more likely this phenomenon occurs. During the closing process of the control valve, the valve expands during resealing, causing the sealing surface to be scratched and rubbed, leading to local wear or indentation of the sealing surface.

  5. Erosion by the medium results from wear, washing, and cavitation of the sealing surface as the medium moves. At certain speeds, particles suspended in the medium contact the sealing surface, causing local damage. High-speed moving medium directly washes the sealing surface, causing local damage. When the medium mixes and partially evaporates, gas bubbles burst and impact the sealing surface, causing local damage. The alternating effects of medium erosion and chemical corrosion strongly erode the sealing surface.

  6. Electrochemical corrosion. Mutual contact between sealing surfaces, contact between the sealing surface and the sealing body and bonnet, as well as concentration differences and oxygen concentration differences in the medium, cause potential differences and electrochemical corrosion, leading to corrosion of the sealing surface on the anode side.

  7. Chemical corrosion of the medium. The medium near the sealing surface directly reacts with the sealing surface, corroding it without generating an electric current.