Selection and Use of Lined Valves
Release date:
2022-12-29
In the chemical industry, many materials are highly corrosive. Under these special operating conditions, the selection of equipment, pipelines, and valves is crucial to ensure the stable operation of the facility. Most corrosive media typically have strong corrosive effects on metals; common metal valves, such as carbon steel and stainless steel valves, are quickly corroded. Currently, a reliable option is fluorine-lined valves. Now, let's learn about the selection and use of fluorine-lined valves.
In the chemical industry, many materials are highly corrosive. Under these special working conditions, the selection of equipment, pipelines, and valves is crucial to ensure the stable operation of the facility. Most corrosive media usually have strong corrosive effects on metals; common metal valves, such as carbon steel and stainless steel valves, are quickly corroded. Currently, a reliable option is fluorine-lined valves. Now, let's learn about the selection and use of fluorine-lined valves.
With the continuous application of new chemical materials and the improvement of lining technology, Fluorine-lined valves are favored by manufacturers and users for their safety, reliability, and cost-effectiveness. Their application is becoming increasingly widespread. However, fluorine-lined valves are not suitable for all corrosive conditions. Like other valves, selecting and using fluorine-lined valves is a professional task.
1. The temperature of fluorine-lined valves should be about 30% below the upper limit.
Fluorine-lined valves Operating temperature: Common valve lining materials currently used include synthetic rubber (-10 to 120°C), polytetrafluoroethylene (PTFE) (-200 to 180°C), perfluoroalkoxy (PFA) (-196 to 260°C), and perfluoroethylenepropylene (F46) (-85 to 150°C). These are the publicly available maximum temperature limits for each material. The actual temperature of the medium depends on the material and pressure. The long-term operating temperature should generally be about 30% below the upper limit. Otherwise, the lining of valve components may deform, causing significant leakage or failure to operate properly.
2. Fluorine-lined valves are not suitable for high pressure or high differential pressure conditions.
Pressure (differential) for fluorine-lined valves: Generally not used in high vacuum conditions. Features like dovetail grooves and valve plate drilling prevent the fluorine or plastic lining inside the valve chamber from being pulled out (bulging), and prevent the lining and metal layers from peeling off, which would cause the valve to malfunction.
Similarly, Fluorine-lined valves they are also not suitable for high pressure or high differential pressure conditions. Especially fluorine-lined bellows sealed control valves (since bellows are mostly made of PTFE, excessive pressure or differential pressure can easily cause bellows rupture). Most manufacturers specify a nominal pressure of PN2.5MPa for safety reasons. However, sometimes special working conditions require finding solutions.
3. The medium should not contain hard particles, crystals, impurities, etc.
Requirements for the medium in fluorine-lined valves: The medium should not contain hard particles, crystals, impurities, etc., to avoid wear on the fluorine (plastic) lining of the valve. During valve opening and closing, the plastic lining or bellows may be damaged. If the medium contains hard particles, crystals, or impurities, corrosion-resistant precious metal materials such as Hastelloy, nickel-based alloys, or alloy steel hard-sealed valves can be selected according to the characteristics of the process medium. The valve diameter should be 30~85%.
Fluorine-lined bellows sealing structures are commonly used, offering advantages such as good corrosion resistance and no leakage. When selecting, the valve diameter should be calculated based on process parameters, and the normal opening should be within the 30-85% range. An excessively large valve diameter will cause long-term operation at small openings, reducing regulation performance. Especially at small openings, not only will erosion be aggravated, but the valve core and stem may vibrate due to the impact of the medium, potentially causing stem breakage and bellows deformation.
The above is an introduction to the selection and use of fluorine-lined valves. For more information, feel free to contact us! Our company has many years of experience and looks forward to your joining at any time.